Purification of waste waters:
- physico-chemical
procedures
- reverse
osmosis
- ultrafiltration
- ion exchange
Recirculation of waste water from a treatment plant, purified with reverse osmosis to the level of demi water for re-rinsing in galvanization industry, including the preparation of watering water with water softening deferisation (Central microprocessor control with Allan Bradley - TOMOS Group d.d., Ljubljana, 1998).
Purification of waste waters from paint rooms and galvanization process
Physico-chemical
procedures of waste water treatment with preparation of rinsing water
with membrane
technology; reverse osmosis. The quality of waste water is adequate for
public
sewer outfall with possibility of after-treatment and recirculation for the water
course outfall.
Completely automated system with supervision and local control Siemens S7.
Microprocessor controlled treatment of waste water for use in laboratories.
-
continuously working disinfection 3 m3/h
- continuously working neutralization 3 m3/h
(Central microprocessor control with Allan Bradley - Veterinary institute
Ljubljana, 2002)
Microprocessor controlled treatment of waste water for use in Nyagan-Russia hospital
-
continuously working disinfection 3 m3/h
- continuously working neutralization 3 m3/h
(Central microprocessor control with Allan Bradley - SMELT / NYAGAN Russia, 2003